  3.                 Remote Control for ICOM Transceivers via PC
  4.  
  5.                   V 2.1  Copyright G.Tamm DF 9 ZO / 1992
  6.  
  7.  
  8. System Requirements    : IBM PC/AT or 100 % compatible
  9.                          Processor at least 80286
  10.                          VGA-Adaptor for Spectrum  
  11.                         
  12. Installation from disc : Change drive to A: or B:
  13.                          Type install, Return
  14.  
  15. Necessary files        : C:\ICOM\icom.exe
  16.                                  icom.mnu
  17.                                  icom.cfg
  18.                                  egavga.bgi
  19.                                  litt.chr
  20.                                  readme
  21.                                  data.tmp
  22.                                  example
  23.                                     +                                 
  24.                                  any name text files for frequency database
  25.                                     +
  26.                                  (install.exe)
  27.                                  (monitor.exe)
  28.  
  29.  
  30. MENUE INFO:
  31.  
  32. -This file.
  33.  
  34.  
  35. MENUE COM 1/2:
  36.  
  37. -Selection of COM 1 or COM 2.Default is COM 1.
  38. -Selection of 1200 or 9600 Baud.Default is 1200 Baud.
  39.  Take care with 9600 Baud when using long cables between device and
  40.  interface or more than one device connected to ICOM-Bus.
  41.  
  42.  
  43. MENUE DEVICE:
  44.  
  45. -Selection of ICOM device adress (Default=4) and datalength (Default=4),
  46.  see examples at end of file.
  47.  (Enter device adress in hex format, for example adress 1C is entered
  48.   as "1" and "C")
  49. -When starting, the program tries to read textfile C:\ICOM\ICOM.CFG 
  50.  for your personal configuration.
  51.  
  52.   Line of file       Example            Meaning
  53.        1               1             COM 1 selected
  54.        2               1200          1200 Baud selected
  55.        3               14            Device adress for IC 475 
  56.        4               5             Datalength 5 byte
  57.     6  -  25                         Frequency and mode data Online Memory
  58.  
  59.  
  60. MENUE FILE:
  61.  
  62. -Enter frequencies in MHz "." kHz "," optional 3 decimals for your
  63.  frequency database.
  64.  
  65.   Examples:
  66.       
  67.          Input                             File 
  68.  
  69.           .5                               .500,000
  70.         14                               14.000,000      
  71.         28.5                             28.500,000
  72.        144.350,5                        144.350,500
  73.       1296.350,000                     1296.350,000
  74.  
  75. -Possible modes are lsb,usb,cw,am,fm.Small letters are possible,
  76.  program converts to capital letters.
  77.  If no mode is entered, "USB" will be selected.
  78.  
  79. -C:\ICOM\EXAMPLE is an example file for working with PC Memory or
  80.  Memory Scan.It shows data format if you want to edit files with
  81.  a text editor.
  82.  
  83. -Sorting of files ( key = frequency ) possible.
  84.  
  85.  
  86. MENUE PC OPERATION:
  87.  
  88. -Menue Online:
  89.  
  90.  Manual operation of device and entered data will be shown on PC display.
  91.  Frequency, date and time as large seven segment, other information as
  92.  normal letters.
  93.  Device is requested continuously to send out actual data.
  94.  
  95.    Enter             Push to enter data, push twice to stay on frequency
  96.                      and change only mode
  97.    Escape            Return to Menue
  98.    F1                Help
  99.    F2                Show Online-Memory List
  100.    a                 Selection of VFO A
  101.    b                 Selection of VFO B
  102.    s                 Enter frequency step for Arrow left/right
  103.    f                 Store displayed frequency, mode, PC date and time
  104.                      in C:\ICOM\DATA.TMP 
  105.    m                 Select Online Memory channel 1 - 20 ( C:\ICOM.ICOM.CFG )
  106.    d                 Show PC date
  107.    t                 Show PC time
  108.    n                 Select narrow bandwidth
  109.    w                 Select wide   bandwidth
  110.    Arrow up/down     Frequency step up/down
  111.                     
  112.                              Mode                Step
  113.                     
  114.                              AM,FM               1 kHz
  115.                              LSB,USB             100 Hz
  116.                              CW                  10 Hz
  117.    
  118.    Arrow left/right  Frequency step up/down, Default 25 kHz, select
  119.                      other steps with "s"
  120.  
  121.  Depending on Icom device displayed 1Hz-frequency data may be dummy data.
  122.  
  123.  
  124. -Menue PC Memory:
  125.  
  126.  Select frequency and mode in any database file and send data to device.
  127.  If program finds a mouse installed, select with mouse.
  128.  
  129.  
  130. -Menue Scan/Spectrum:
  131.  
  132.  Enter lower and upper frequency, mode, scanstep and holdtime.
  133.  
  134.   Start                            Any key
  135.   Stop                             Return
  136.   1 Scanstep up                    Return, if stopped before 
  137.   Scan again                       Any key but not Return
  138.   Escape                           Return to menue
  139.  
  140.  Devices connected to ICOM-Bus are not adressed because of transmission
  141.  time via serial port, every device scans inside its frequency range.
  142.  With additional equipment spectrum operation and monitoring is possible 
  143.  (VGA-Mode), see remarks.
  144.  
  145.  
  146. -Menue Memory Scan:
  147.  
  148.  Select any database file for scanning, then same operation like Scan.
  149.  
  150. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
  151.  
  152.  Examples for ICOM adresses and datalength :
  153.  
  154.  Adress:                Datalength:
  155.  
  156.  R 71    : 1A
  157.  R 72    : 32
  158.  R 7000  :  8
  159.  R 7100  : 34
  160.  R 9000  : 2A
  161.  
  162.  IC 271  : 20
  163.     275  : 10
  164.     375  : 12
  165.     471  : 22
  166.     475  : 14                5 
  167.     575  : 16
  168.     725  : 28
  169.     726  : 30
  170.     735  :  4                4
  171.     751A : 1C
  172.     765  : 2C                4/5 adjustable at device
  173.     761  : 1E
  174.     781  : 26
  175.     970  : 2E
  176.     1275 : 18
  177.  
  178. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++  
  179.  
  180.  A positive signal ( TTL level may be possibly enough ) connected to RI 
  181.  of COM-port used for ICOM interface stops scanning while operating 
  182.  Scan/Spectrum or Memory Scan. 
  183.  Scanning goes on with RI-signal going to ground or pushing any key 
  184.  (1 scanstep up with Enter).
  185.  See your ICOM-Manual for polarity of SQL-signal at ACC-port, invert 
  186.  SQL-signal if necessary.
  187.  Holdtime must not be too short to allow AF to stabilize.
  188.  
  189. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
  190.  
  191.  Remarks for Spectrum - Operation :
  192.   
  193.  -Operate COM-port with 9600 Baud because of serial transmission time and
  194.   faster mode of operation.
  195.   Adjust ICOM device to 9600 Baud internally by jumpers.
  196.  -Operation of devices will be in ICOM-Mode 0, no device message.
  197.  -Disconnect RX and TX at ICOM-Bus in your interface   ONLY! 
  198.   for spectrum operation. 
  199.   Connect an A/D converter with serial conversion to RX of interface.
  200.   (With RX and TX connected you will see the converted remote messages for 
  201.   the device) 
  202.  -ICOM data format (hex) :
  203.   
  204.   FE_FE_00_PC Adress_00_Remote data (4/5 byte)_FD     
  205.  
  206.  -After end of holdtime the A/D converter is requested to send
  207.   one character (8 bit) :  
  208.   
  209.   Startbit_1 character_1 Stopbit         no parity
  210.  
  211.   At DTR of COM-port used for interface will be a Sync-signal
  212.   for A/D conversion.The A/D converter may not be allowed to send
  213.   continuously because of receive-buffer overflow of COM-port.
  214.  -A COM-Monitor (Monitor.exe) is supplied with the program to make 
  215.   checking easier.  
  216.  
  217. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
  218.  
  219.  Simple ICOM interface :
  220.  
  221.  RS 232               +5 V
  222.                         |
  223.                         |           2 X C  
  224.                         o------4,7 n || 10 uF--------| Gnd
  225.                         |
  226.                       R 10 K                              ICOM remote jack
  227.                         |                                      or ICOM-Bus
  228.  GND o----------|       o------------o-----------------o---L 1uH--------o                 
  229.                Gnd      |            |                 |
  230.           R          |-- C           |                 |
  231.  TX  o--47 K----o----|               |                 |                o
  232.                 |    |-- E           |                 |                |
  233.                K|       |            |                 C                |
  234.             D 1N4148    |            |               100 p              |
  235.                A|       |            |                 |                |
  236.                _|_     _|_           |                _|_              _|_
  237.                Gnd     Gnd           |                Gnd              Gnd 
  238.  RTS o---                            |                            ICOM Gnd
  239.         |                            |                      
  240.  CTS o---              +5 V          X   disconnect here when  
  241.                         |            |   operating with A/D
  242.                         R            R
  243.                       4,7 K        6,8 K 
  244.                         |            |
  245.                       C |            |
  246.  RX  o------------------o-|          |
  247.                           |----------o
  248.                         --|          |
  249.                       E |            |
  250.                         |            R
  251.                         |           22 K
  252.                        _|_          _|_
  253.                        Gnd          Gnd
  254.  
  255.  -----------Optional : Sync for A/D and Scan stop-------------------------
  256.  
  257.                                                           Sync OUT for A/D
  258.  DTR o---------------------R 1 K-----------------------o----------------o
  259.                                                        |
  260.                                                       K|
  261.                                                     Z 4,7 V
  262.                                                       A|
  263.                                                       _|_
  264.                        +5 V                           Gnd
  265.                         |
  266.                       R 3,3 K  
  267.                         |
  268.                        C|                  |
  269.  RI  o------------------o-|                |                  Scan stop IN
  270.                           |------R 2,2 K---o----------------------------o
  271.                          -|                |    invert signal if necessary
  272.                        E|                  |
  273.                        _|_        R 4,7 K to +5 V or Gnd
  274.                        Gnd        depending on SQL signal polarity
  275.  
  276.  An Interface with all necessary cables is also available from ICOM
  277.  
  278. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
  279.  
  280.  Not all functions of the program are available with every ICOM device !
  281.  
  282.  No guarantee, no warranty, no liability when using the program !